Response from Trenchless Innovations Inc.:
Thank you so much for this review. We really appreciate your business and helping to share the word about us.
Televised sewer from inside floor clean out and Lund that the cast is scaled. Suggest changing power flush toilets to Gerber Avalanche toilets. Also suggest descaling cast iron from cleanout and also from pulled toilet in men’s room
Pulled master bath toilet to pull in 3’ patch liner from 6” pvc outside clean out to position over 4” 90 elbow with 360 fracture/crack behind glue joint allowing root to grow into line.
Sewer was backed up so needed to be Rodded. Rodded approximately 70ft and could not get past with a 4” cutter. Pulled out and tried with a bent end and same result. Cutter blade and bent end came back shiny indicating a break. Located with the camera. Break is in the neighbors driveway approximately two ft deep and about two ft from curb. Suggest this spot be dug up and repaired.